The property that makes UV-C useful, its damage to genetic material, also makes it a hazard to people. Safe systems keep exposure below recognised limits by design. This article explains the limit, how to check a space against it, and the controls to use in air-handling units and rooms.

What UV-C does to skin and eyes

  • Eyes: photokeratitis, a painful inflammation of the cornea sometimes called welder’s flash. It feels like sand in the eyes.
  • Skin: erythema, a reddening similar to sunburn.

Both usually appear several hours after exposure, and nothing is felt at the time. Someone can be over-exposed without noticing until later, which is why limits and engineering controls matter more than caution alone.

The exposure limit

For 254 nm radiation, widely used occupational guidance, including the ACGIH threshold limit values and the limits in IEC 62471, sets a maximum of 6 mJ/cm² over an 8-hour day. That corresponds to an average irradiance of about 0.2 µW/cm² for a full working day. The permitted time at a given irradiance is:

permitted time (s) = 6,000 µJ/cm² ÷ irradiance (µW/cm²)

Irradiance at eye or skinPermitted exposure per day
0.2 µW/cm²8 hours
1 µW/cm²100 minutes
10 µW/cm²10 minutes
100 µW/cm²60 seconds
1,000 µW/cm²6 seconds

For comparison, the surface of a cooling coil near the lamps often receives 1,000 µW/cm² or more. A person looking into an open unit with the lamps on can exceed the daily limit in seconds.

Air-handling units

  • Fit door and panel interlocks that switch the lamps off whenever the unit is opened.
  • Use viewing windows that block UV-C if staff need to check the lamps are running.
  • Lock out and isolate the lamps before maintenance.
  • If work with lamps on is unavoidable, wear a face shield rated for UV and cover all exposed skin.
  • Label every access door with a UV-C warning.

Rooms

  • Run room systems only when the space is empty, using timers, occupancy sensors and door interlocks.
  • Put warning lights and signs at every entrance.
  • Where people may be present while lamps are on, for example with upper-room fixtures, calculate the irradiance at eye level and check it against the limit for the time people spend there.

See UV-C in food processing for how this works in practice in processing rooms and cold stores.

Ozone, materials and broken lamps

  • Ozone: some lamps also emit at 185 nm, which produces ozone. Specify ozone-free lamps, whose glass blocks that line.
  • Materials: UV-C degrades many plastics, rubber seals, cable insulation and filter media. Shield them or choose UV-resistant materials.
  • Breakage: low-pressure lamps contain a small amount of mercury. Follow the manufacturer’s clean-up guidance and dispose of used lamps as hazardous waste.

Further reading

ISO 15858 covers safety information and permissible human exposure for UV-C devices, and IEC 62471 covers the photobiological safety of lamps. Local workplace regulations always take precedence, so check them for each site.